With higher water prices during a drought, saving water anyway you can will save a lot of money.

Water treatment systems including water softeners, reverse osmosis systems, iron filters and other types of backwashing and self-cleaning treatment systems all produce wastewater, which flushes out accumulated contaminants.

It is very common for these filter systems to be installed and then forgotten about; if the system is set to backwash more frequently than needed, you could be unnecessarily wasting water. This wasted water can be reduced with a few simple steps.

The Top 5 Steps To Reduce Water Treatment Waste Water

  1. Identify the type of system you have
  2. Test the water before and after the system to see how it is working
  3. Check the settings
  4. Change the settings to optimize water use
  5. Re-test and monitor the water before and after the system

Water Softeners

Water softeners take out calcium hardness from water with a method known as ion-exchange. The process back-washes as well as cleans the softening resin by way of a salt brine solution. In the course of the regeneration cycles, a quantity of waste water is produced, which cannot be re-used for garden water and is sent to the sewer or septic tank.

Most water softeners have a flow sensing unit, that meters the quantity of water being used which allows the softener to back-wash and regenerate, based on the quantity of water the softener has utilized in between regenerations

How To Minimize Water Softener Water Waste

  1. Check hardness levels before and water softener
  2. Check to see the number of gallons (or days if it is a time-clock type control) between regeneration cycles that the softener is currently set to regenerate
  3. Determine how many pounds of salt, for each cubic foot of resin, the conditioner is currently set to use for every regeneration
  4. Modify the settings to allow for more days between regeneration cycles
  5. Adjust the lbs of rock salt used, if greater than 9 lbs of salt per cubic foot
  6. Monitor water softener and on the day before the regeneration, and verify that the water continues to be softened to make sure the settings have not been too aggressive.

Iron Filtration and Other Types of Back-Washing Filter Systems

Iron filters, carbon backwash filters, acid neutralizer filters, as well as turbidity filters virtually all use some water to periodically backwash and rinse out the filter media which the system uses. Just like water softeners these filter systems can backwash depending on the amount of water used, and / or they may be simple time clock controls that backwash according to the day of the week, and / or days or weeks between backwashes.

How To Decrease Backwash Filter Waste Water

  1. Analyze water both before and after system (for pH, iron, sediment etc)
  2. Check to see how many gallons (or days if a time clock type filter) between
    regeneration cycles the filter system is currently set to backwash
  3. Determine how long the particular backwash cycle is, and how many minutes the rinse cycle is set for
  4. Modify the settings to allow for more gallons or days in between backwash cycles
  5. Adjust the amount of minutes the backwash and rinse cycles are set for. Set for the minimal number minutes advised by the manufacturer. Typically this will be 6 to 8 minutes for backwash, and 4-6 minutes for rinse cycle.
  6. Monitor filter and test the water frequently, both before and after the filtration system, on the day before the next backwash, to verify the water continues to be acceptable.
  7. Look out for changes in water quality and/or a reduction in water pressure, which may signify fouling of the filter media due to inadequate backwashing.
  8. Do not make big reductions in time or days between cycles. Start by reducing it by 10 or 20 percent in order to avoid fouling your filter media.

Point-Of-Use Reverse Osmosis Systems

Reverse Osmosis devices take out total dissolved solids, dissolved salt and metals from water through a membrane process known as “reverse osmosis”. They have cartridge filters that filter your water of chlorine, chemicals, tastes and odors. In the RO process, the membrane sends waste water to the drain at the same time allowing pure water reduced in TDS to permeate through the RO membrane.

How You Can Reduce Reverse Osmosis Waste Water

  1. Analyze your water before and after RO system for TDS to make certain RO is eliminating at least 90% of the Total Dissolved Solids.
  2. Keep pre-filters changed regularly. A clogged pre-filter may foul the RO membrane and reduce the amount of pure water being produced, which can increase the volume of waste water.
  3. For best results, drain the RO tank entirely each time you use the pure water. This can allow the RO membrane to produce the most quantity of pure water, while losing the least volume of water. As the RO pressure tank gets completely full, the volume of pure water produced is much less, even though the amount of waste water stays the same, so it's far better to operate on an empty tank whenever possible.
  4. Consider switching to a new more efficient RO system or retro-fitting your RO, and use a so-called ‘permeate pump', which mimics the effects of the empty RO tank, and permits the system to utilize significantly less waste water.
  5. Empty the RO tank through the faucet, and check the air pressure in the RO pressure tank. Be sure it is adjusted to 7 to 9 PSI and / or observe the manufacturer's instructions in order to keep air pressure within the tank at a proper level. If the RO pressure tank loses pressure, the system will not function effectively.
  6. If it is feasible, during irrigation season look at routing the RO waste water line outdoors to shrubbery or landscaping to re-use for watering.
  7. If your system had been put in professionally, consider contacting your water treatment professional and then schedule a service call. The water treatment pro can easily look at your system and improve it to reduce waste water, while keeping a high level of water quality!

For more help on saving water on your backwashing system, don’t hesitate to e-mail us at support@cleanwaterstore.com, leave us a message on Facebook, or use our online contact form for prompt, personalized assistance from our trained professionals.  Thanks for reading!

Gerry Bulfin

Gerry Bulfin is a licensed water treatment contractor and consultant based in Santa Cruz California and founder and owner of Clean Water Systems and Stores Inc. Gerry is a long time member of the National Ground Water Association, the American Water Works Association (AWWA) and the Water Quality Association (WQA).

Recent Posts

PFAS Treatment for Drinking Water: A Guide for Homeowners on Well Water

PFAS Treatment for Drinking Water is needed in many areas of the U.S. and Canada.…

1 month ago

Understanding Chlorine Skin Effects: A Comprehensive Guide

Chlorinated City Water Can be Tough on Your Skin Living in the city has its…

3 months ago

Navigating Hair Care in Hard Water Areas: A Comprehensive Guide to Treating Well Water Hair Damage

Do you have Well Water Hair Damage? Embarking on a journey through the complexities of…

4 months ago

No Salt Water Softener for the Whole House and Family?

Earlier this week a customer wrote to us asking for a whole-house filter and a…

6 months ago

How to Read Your Water Test Report

Understanding Your Well Water Test Report How to read your water test report?  Since you…

8 months ago

How To Fix Well Water That Smells Bad? Simple Actions to Take.

Rotten-egg smell in your well water? Fix well water that smells bad: 1. Aerate water…

8 months ago