Find the Clean Water Store MetSorb arsenic filter for your peak flow, and estimate how long the media lasts. Media life is calibrated against Graver Technologies calculator data.
| Parameter | Value |
|---|---|
| Media Type | Crystalline TiO₂ (Anatase) |
| Bulk Density | 0.65 g/cc (40 lb/ft³) |
| Particle Size | -16/+60 U.S. mesh |
| Surface Area | 200–240 m²/gram |
| Service Flow Rate | 5 gpm/ft² (Maximum 10) |
| Contact Time (EBCT) | 3 minutes minimum |
| Backwash Rate | 5 gpm/ft² routine (4 minimum; 7 for recovery only) |
| Backwash Frequency | Initial + monthly (or 8–10 weeks) |
| Backwash Volume | 5–7 bed volumes (35–50 gal per cu ft) |
| pH | Under 8.0 (8.0–8.5 shorter life; over 8.5 correct pH first) |
| Arsenic 50 ppb or more | Two tanks in series (lead/lag) |
| Min Bed Depth | 24 inches |
| Max Feed Temp | 150°F |
| Disposal | Non-hazardous (TCLP & CA WET) |