MetSorb® HMRG
Arsenic Filter Calculator

Find the Clean Water Store MetSorb arsenic filter for your peak flow, and estimate how long the media lasts. Media life is calibrated against Graver Technologies calculator data.

1
Your Home
We size MetSorb for at least 3 minutes of contact time at your design flow (2 GPM per bathroom, Graver's rule), and check that the tank's Maximum rating covers your full peak (2 GPM more for the kitchen and washer).
2
Water Quality
ppb
%
As(V) is easier to remove. If unknown, use 80%.
pH
Under 8.0: recommended. 8.0–8.5: allowed, media life will be shorter. Over 8.5: not suitable, correct the pH first.
ppm
ppb As(V)
EPA MCL = 10 ppb
Optional, from a full water test (leave blank if not tested):
µg/L
µg/L
µg/L
mg/L
3
Water Use
Media life uses your daily water use: 75 gallons per person, or your own number under "Know your peak flow?" in section 1.
MetSorb HMRG — Estimated Performance
MetSorb HMRG Specifications
ParameterValue
Media TypeCrystalline TiO₂ (Anatase)
Bulk Density0.65 g/cc (40 lb/ft³)
Particle Size-16/+60 U.S. mesh
Surface Area200–240 m²/gram
Service Flow Rate5 gpm/ft² (Maximum 10)
Contact Time (EBCT)3 minutes minimum
Backwash Rate5 gpm/ft² routine (4 minimum; 7 for recovery only)
Backwash FrequencyInitial + monthly (or 8–10 weeks)
Backwash Volume5–7 bed volumes (35–50 gal per cu ft)
pHUnder 8.0 recommended; 8.0–8.5 allowed, shorter media life; over 8.5 not suitable, correct the pH first
Arsenic 50 ppb or moreTwo tanks in series (lead/lag)
Min Bed Depth24 inches
Max Feed Temp150°F
DisposalNon-hazardous (TCLP & CA WET)
Pre-treatment: Install a dual-grade 50/5 micron sediment pre-filter ahead of the arsenic filter (Big Blue dual-grade 50/5 micron filter, 4.5" x 20"; Replacement cartridge). Iron < 0.3 ppm, Mn < 0.04 ppm. pH under 8.0. If H₂S is present, additional pre-treatment is required. Install MetSorb before a softener, not after it (a softener ahead costs 15% or more of media life).