Required Capacity
—
grains between regenerations
Compensated Hardness
—
GPG (hardness + iron)
How We Calculate
Capacity needed = Compensated Hardness (GPG) × Daily Water Use (gallons) × Days Between Regeneration
Compensated Hardness = Water Hardness + (Iron ppm × 4 GPG)
Softener resin provides ~30,000 grains per cubic foot at the standard salt setting (15 lbs/cu ft), ~20,000 at the efficient setting (6 lbs/cu ft)
Daily use = 75 gallons per person (or your own number). Peak flow = 2 GPM + 2 GPM per bathroom (kitchen and washer included), or your own number.
Flow: the softener's Maximum flow rating (Clean Water Store Spec Master) must cover your peak flow.
Salt efficiency tip: A softener achieves best salt efficiency when you use about 6 lbs of salt per cubic foot of resin (~20,000 grains/cu ft). Using 15 lbs/cu ft gets ~30,000 grains. Oversizing slightly and regenerating more often with less salt saves salt and money in the long run.