Free Fast Shipping
In the Continental U.S.
Water Experts
WQA Certified Technicians
Soda Ash Well Water Package J-Pro-38 with Solution Tank
Frequently Bought Together
Price Total
Description
specs
warranty
Info
Documents
Description
J-PRO-38 Soda Ash System with Solution Tank
Neutralize acidity and reduce corrosion in pipes and equipment
- The complete system includes a soda ash pump, solution tank, injection check valve, tubing, and fittings.
- Just mix soda ash powder with warm, soft, or pure water, then add it to the solution tank; it's easy to do and lasts for several months.
- Uses readily available soda ash powder (sodium carbonate), safe and certified for drinking water use.
- Heavy-duty metering pump systems are designed to last for many years with minimal maintenance.
- Choose model 110V or 220v 50/60hz.
- Works over a wide range of water flow rates for most home water wells.
- Good for well water flow rates from 1 to 40 Gallons Per Minute. Contact us for systems for higher flow rates over 40 GPM.
- Pumps 3 to 38 gallons of solution per day.
- Works for line pressures up to 110 PSI.
- Low power consumption: uses only 22 watts or 0.2 amps.
- Easy to adjust the pump quickly for accurate injection and precise pH control.
- Unlike Stenner-style peristaltic pumps: no pump tube failures, no rollers to go bad, needs less service, and good for continuous duty.
- Pump mounts easily on the top of the tank or on a wall.
- Primes fast, and doesn't easily lose its prime when properly installed.
- Plug into a Flow Switch (sold separately) or wire to your standard pressure-switch pump system.
What is included?
- J-PRO-38 Soda Ash Pump
- 10. 15, 25, or 50-gallon heavy-duty polyethylene (HDPE) solution tank
- Tubing and fittings to connect the pump to the injection check valve and solution tank
- 1 Injection Check valve 1/2" male pipe thread
- Suction tubing and a foot valve to connect the solution tank to the pump
- Priming valve to make it easy to prime the pump
- Easy to read Manual
- Free pH test kit
- Free ground shipping in the continental U.S. Air shipping and expedited shipping are available.
Free Expert Technical Setup & Support
Since 1986 we have installed many hundreds of chlorination systems worldwide. We can offer you expert advice on the exact type of soda ash solution to use, how much to use and what settings to use with your new system. These pumps are the easiest and most accurate soda ash pumps available on the market today!
Loaded with features only found in much more expensive industrial metering pumps, our J-PRO-38 Metering Pump makes soda ash and other chemical injection fast and accurate. Our easy-to-use installation guide will guide you through the steps, but if you need help or have questions, we are just a phone call or email away.
Loaded with features only found in much more expensive industrial metering pumps, our J-PRO-38 Metering Pump makes soda ash and other chemical injection fast and accurate. Our easy-to-use installation guide will guide you through the steps, but if you need help or have questions, we are just a phone call or email away.
What size solution tank should I order?
- We recommend the 25 or 50 gallon tank.
- Most of our customers use 5 to 10 gallons soda ash solution per month.
Should I add a Flow Switch, or should I choose a Proportional Flow Meter?
Many customers skip the flow switch and flow meter and just wire directly to the well pump circuit. Choose a 220V model (most wells pump systems are 220V) unless you know your well pump is 110V (not typical).What type of soda ash should I use?
We recommend using NSF certified soda ash powder and mixing it with purified RO water or soft water.
Should I use a contact retention tank?
Should I use a static mixer?
What is the warranty? How long do these systems last?
- The system includes a one year manufacturer warranty.
- You can usually expect 4 to 6 years life however all components are serviceable and replaceable.
- Use purified or soft water to make up your solution and follow recommended routine maintenance for best results.
- The system includes a one year manufacturer warranty.
- You can usually expect 4 to 6 years life however all components are serviceable and replaceable.
- Use purified or soft water to make up your solution and follow recommended routine maintenance for best results.
3 Ways To Set Up Your Soda Ash Injection System To Turn On Automatically:
Option 1: WIRE TO WELL PUMP PRESSURE SWITCH
Wire to your well's pressure switch. This is the lowest cost method. Simply install a dedicated wall outlet that is wired into the existing pressure switch and powered whenever the well pump turns on (and off). This ensures the soda ash pump runs only when the well pump is operating.


Option 2: PRE-WIRED FLOW SWITCH
Install a pre-wired flow switch. This makes installation fast and easy. No electrical wiring is required and any plumber, or person familiar with basic plumbing, can install the soda ash injection system. No electrician required.
Simply install the pre-wired flow switch. Plug the flow switch into a standard 120V wall outlet. Then plug the soda ash metering pump into the electrical outlet on the flow switch. Whenever there is water flow, the metering pump will turn on automatically.

Install a pre-wired flow switch. This makes installation fast and easy. No electrical wiring is required and any plumber, or person familiar with basic plumbing, can install the soda ash injection system. No electrician required.
Simply install the pre-wired flow switch. Plug the flow switch into a standard 120V wall outlet. Then plug the soda ash metering pump into the electrical outlet on the flow switch. Whenever there is water flow, the metering pump will turn on automatically.

Option 3: PROPORTIONAL - FEED FLOW METER TYPE
Select the Pulse Water Meter option. This is a proportional-feed type of installation. It is very easy to set up and requires no electrical wiring or electrician. A flow meter (water meter with electrical cable connected to the metering pump) is installed which triggers the soda ash pump based on actual water flow.
When there is water flow through the meter, the pump will inject a programmed amount of soda ash solution into each gallon as it passes, regardless of flow rate.
Simply install the flow meter and connect the cable to the metering pump. Plug the pump into a standard 120V wall outlet. When the water flows, the pump adjusts injection automatically based on flow rate.
NOTE: Unlike Option 1 and Option 2, the injection check valve is installed AFTER the pressure tank. This option also allows you to inject soda ash after a lateral line to irrigation or any line you do not want to treat.

Select the Pulse Water Meter option. This is a proportional-feed type of installation. It is very easy to set up and requires no electrical wiring or electrician. A flow meter (water meter with electrical cable connected to the metering pump) is installed which triggers the soda ash pump based on actual water flow.
When there is water flow through the meter, the pump will inject a programmed amount of soda ash solution into each gallon as it passes, regardless of flow rate.
Simply install the flow meter and connect the cable to the metering pump. Plug the pump into a standard 120V wall outlet. When the water flows, the pump adjusts injection automatically based on flow rate.
NOTE: Unlike Option 1 and Option 2, the injection check valve is installed AFTER the pressure tank. This option also allows you to inject soda ash after a lateral line to irrigation or any line you do not want to treat.

Can I install this myself? Can I have my plumber or handyman install it?
- Yes, you can install it yourself, however a local plumber or handyman can also install it for you.
- In addition to the easy to read manual, we also have youtube videos that walk you through the installation below.
- To make it easier for a plumber or handyman to install we recommend the optional Schedule 80 PVC Injection Tee (see drop down menu).
- If you want to avoid having to do any wiring we recommend the proportional feed or flow switch options.
- The chlorinator typically takes about 2 - 3 hours to install.
Watch: How to set up your Chemical injector pump — Step by Step
Not sure how to get your chemical injection pump installed and running correctly? Clean Water Store Technical Support Manager Bryan Bowdle walks you through the entire setup process in this straightforward instructional video — from mounting your pump and connecting your foot valve and injection check valve, to priming the system and choosing between manual and proportional mode. Whether you're injecting chlorine, soda ash, or hydrogen peroxide, getting your pump dialed in correctly from the start makes all the difference for consistent, reliable water treatment. Watch the full walkthrough below. We also have a video showing how to do the tubing here.
Specifications
Specifications
| Pump Model | J-PRO-38 electronic diaphragm metering pump |
|---|---|
| Maximum Pump Output | 6 liters per hour, approximately 38 gallons of solution per day |
| Approximate Output per Stroke | Approximately 0.625 cc per stroke at 100% stroke length |
| Maximum Operating Pressure | 8 bar, approximately 116 PSI |
| Recommended Water-Flow Range | Suitable for many residential well-water pH correction applications from approximately 1 to 50 GPM. Actual capacity depends on soda ash solution concentration, required dosage, incoming pH, and pump settings. |
| Recommended Soda Ash Solution | Food-grade or NSF-certified sodium carbonate (soda ash) dissolved in water. A standard mix of 2 to 3 lbs of soda ash per gallon of water produces a 10% solution suitable for most residential pH correction applications. Use purified or softened water for mixing to prevent scale buildup in the solution tank and tubing. |
| Typical Injection Rate | Target a treated water pH of 7.0 to 8.0. Inject at 100 to 200 ppm of soda ash solution as a starting point for most residential applications with incoming pH between 5.0 and 6.5. Adjust injection rate based on measured pH at the tap after installation. A contact tank downstream improves mixing and pH stability. |
| Pump Adjustment | Adjustable stroke length and stroke frequency provide accurate chemical-feed control |
| Operating Modes | Manual operation or external proportional pulse control |
| Voltage | Available in 110V or 220V models, 50/60 Hz |
| Power Consumption | 30 watts or less |
| Pump Type | Electronic solenoid-driven PTFE diaphragm metering pump |
| Pump-Head Material | Polypropylene pump head with PTFE valve seats and EPDM seals and O-rings. Compatible with sodium carbonate solutions at standard residential concentrations. |
| Enclosure Rating | IP65 |
Solution-Tank Options and Dimensions
Choose from four heavy-duty polyethylene solution-tank sizes. Dimensions shown include the J-PRO-38 pump mounted on the tank and are listed as approximate width × overall height.
| Solution-Tank Capacity | Approximate Overall Dimensions |
|---|---|
| 10 Gallons | 14 inches wide × 24 inches high |
| 15 Gallons | 16 inches wide × 29 inches high |
| 25 Gallons | 18 inches wide × 32.5 inches high |
| 50 Gallons | 22 inches wide × 41.5 inches high |
Tank-size recommendation: The 15-gallon or 25-gallon tank is recommended for most home well-water applications. Most residential systems do not require the 50-gallon tank. Mix only enough fresh solution to last approximately 4 to 8 weeks. Rinse the tank periodically and replace solution regularly to prevent biological growth.
Calibration note: Actual chemical output can vary with line pressure, suction lift, solution viscosity, tubing condition, and pump settings. Verify treated water pH at the tap using a pH test strip or meter after calibration and adjust injection rate as needed to reach the 7.0 to 8.0 target range.
Warranty
1 Year Warranty from date of delivery
If your pump fails under warranty, please call or email our office to obtain a Returns Good Authorization Number before sending us back the pump for repair or replacement under the warranty. No returns can be accepted without an RGA number. The warranty covers repair and/or replacement of the metering pump but not shipping costs.
While defects are rare, we do our best to respond to warranty returns as fast as we can. Please allow 3 to 5 business days after the pump has been returned for your pump to be repaired or a new one supplied under the warranty agreement. If the water supply and its continuous chlorination are critical, a back-up chlorinator pump should be on hand. Shipping charges are not covered under warranty. Any expedited shipping (overnight, 2-day, etc.) is the customer's responsibility.
Conditions Not Covered by the Warranty:
Power surges or outages that cause pump failure are not covered under warranty. Surge protection is strongly recommended. If a pump is returned for warranty replacement and the cause of failure is determined to be from a voltage spike, the pump does not qualify for replacement. This is the leading cause of failure. Pump failure during, or because of, power failure is not covered under warranty.
This pump is intended for indoor use only. The pump must never be exposed to freezing temperatures, direct sunlight, or rain. If the cause of failure is determined to be from exposure to any of these environments, the pump does not qualify for replacement and will not be covered under warranty.
Request a Call




